Guide

Cutting heating costs in guesthouses and hotels

Lower empty rooms, preheat in time before arrival – save heating energy without a guest ever walking into a cold room.

In many small properties every radiator runs the same, whether someone is sleeping in the room or it has been empty for a week. Yet on most days a large share of the rooms is not occupied. That is where the biggest saving lies: heat rooms by occupancy, not by the calendar.

Why empty rooms cost so much

A common rule of thumb: every degree less room temperature saves about 6 % of heating energy. An empty room kept at 16 °C instead of 21 °C therefore needs roughly a quarter to a third less energy during that time. At 50–60 % occupancy, almost every second room night is empty – and is often heated fully anyway.

The right temperatures

  • Occupied room: 20–21 °C feels comfortable for most guests. The bathroom can be a little warmer.
  • Empty room: 16–17 °C. Don't go much lower: cold walls attract moisture, the risk of mould rises and reheating takes longer.
  • After departure: air and clean first, then lower – while the window is open, the heating should be off anyway.
  • Corridors, breakfast room: heat only when they are in use.

Preheating: when does the heating need to go up?

The most common objection: “Then the room is cold when the guest arrives.” A fixed preheating time solves that. With ordinary radiators, 2–3 hours are usually enough to bring a room from 16 to 21 °C. Old buildings with thick walls or large rooms need a bit more. Underfloor heating reacts very slowly – lowering only pays off there for longer vacancies of several days.

Count back from your usual check-in time: if check-in starts at 3 pm and the room needs three hours, preheating starts at noon.

Example calculation

A guesthouse with 10 rooms, heating costs of about €600 per room per year, 55 % occupancy. So far all rooms are kept at 21 °C around the clock.

  • Empty room nights: 45 % of the time
  • 5 °C less during that time: about 30 % less energy (5 × 6 %)
  • Saving: 45 % × 30 % ≈ 13 % of heating costs
  • With €6,000 heating costs a year, that is around €800

This is a rough estimate – building, heating system and weather matter a lot. But the order of magnitude shows that occupancy-based heating pays for itself within a few heating seasons.

Manual or automatic?

You can turn the thermostats down by hand when cleaning after departure, and back up in time before the next arrival. In practice this rarely works reliably: sometimes it is forgotten, sometimes a last-minute booking comes in, and at weekends nobody is around.

Smart radiator thermostats solve that. They can be controlled by app or software and cost roughly €50–90 per radiator depending on the system, plus a hub or bridge. Common systems include Homematic IP and tado°. Most also detect open windows and briefly turn the heating off.

The real gain only comes when the thermostat knows whether a room is occupied. A simple weekly schedule (“Mon–Fri 6 am–10 pm warm”) does not fit changing bookings. Control should therefore come straight from the booking calendar.

Checklist

  1. Bleed the radiators and check that they all heat evenly.
  2. Set a comfort and a setback temperature (e.g. 21 °C and 16 °C).
  3. Find your preheating time: measure once how long a room takes from 16 to 21 °C.
  4. Fit smart thermostats in the guest rooms – usually possible without a tradesperson.
  5. Connect the thermostats to the booking calendar so arrivals and departures control the temperature.
  6. Briefly tell guests that they can adjust the temperature on the thermostat themselves.

Frequently asked questions

Will guests be cold if I lower empty rooms?

No, as long as the room is preheated in time. With radiators, two to three hours before check-in are usually enough. What matters is that preheating is tied to the booking automatically and cannot be forgotten.

How far can I lower an empty room?

Around 16 to 17 °C is a good value. Much lower, the risk of moisture and mould rises and reheating takes longer.

Is it worth it with underfloor heating?

Only for longer vacancies of several days. Underfloor heating reacts so slowly that lowering it for a single night hardly pays off.

Can guests change the temperature themselves?

Yes. Smart thermostats can still be adjusted on the device. A good automation only steps in again at the next change, i.e. at departure or the next arrival.

Occupancy-based heating with Stay-Board

With the Heating control module you connect Homematic IP or tado° thermostats to your rooms. Stay-Board preheats in time before every arrival and lowers the temperature after departure – hourly and automatically from the booking calendar. You set the comfort and setback temperatures and the preheating time yourself. More about the module

Start free

← Back to the guide